Knowledge Base

Everything you need to understand plasma technology all in one place.

Knowledge Articles

Let’s Talk About… How long plasma treatment lasts?

The most commonly asked question concerning plasma surface treatment is; How long does plasma treatment last?

In this ‘Let’s talk About…’ article we discuss the main factors that influence the lifetime of plasma surface treatments and explain how these factors can affect different materials.

Plasma surface treatment is an established and effective method of improving the adhesion characteristics of a wide range of materials.  Even for the most challenging polymers such as PET, PPS, PEEK, PTFE, acetals (POM), polyamides and polyolefins, plasma treatment is a fast and reliable process to increase the surface energy of a material, thereby making it easily wettable.

how long does plasma treatment last

Wettability refers to the ability of ink, paint or adhesive to spread on a surface and form intimate contact and strong chemical bonds with surface molecules. Most polymers are naturally hydrophobic, meaning that liquids bead up on the surface and do not form the large numbers of strong bonds which are a pre-requisite for good adhesion.  Metals, glass and ceramics by contrast are naturally hydrophilic, however surface contamination is often present from the machining/production processes which impede adhesion to these materials also. Surface contamination may also be present on many engineering polymers in the form of e.g. mould release agents, plasticizers, pigments and antioxidants.

henniker plasma surface energy test pen results

Plasma surface treatment works by a two-fold action; (i) removal of contamination from the surface (cleaning) and (ii) increasing the surface energy by the attachment of oxygen-containing molecules (activation). Cleaning takes place on all surfaces whereas activation tends to apply mainly to polymers.

What causes Plasma Treatments to decay?

In the case of plasma cleaning, parts will tend to remain in a cleaned state indefinitely as long as they are stored under clean conditions and are free from atmospheric contaminants or from the transfer of oils and salts by e.g. touching with bare skin. 

The situation is a little more complex in the case of polymers. The cleanliness factors above still apply but surface activation is now dominant in increasing the surface energy of the material. The reduction in the effectiveness of plasma treatment over time, i.e. the reduction in surface energy, is known technically as hydrophobic recovery. The bulk properties of a plasma-treated material remain unchanged in comparison to the surface and over time the molecules from within the bulk may migrate to the surface through thermodynamically driven reorientation, causing the oxygen-containing polar groups to be relocated underneath the surface.

This recovery is to a large extent a characteristic of the material rather than the plasma treatment and we will discuss some reasons for this below.

Type of material

The characteristics of the material undergoing plasma treatment are one of the most important factors that affect the rate of hydrophobic recovery. Some polymers are more tightly packed, and the sub-surface molecules have less freedom of movement, hindering their ability to relocate to the surface and thus slowing down the recovery process. Conversely, lower density polymers can more easily reorientate and the oxygen-containing surface molecules will in turn migrate into the bulk. Low molecular weight additives such as plasticizers and pigments will, if present, also migrate back to the surface over time.

Figure 1 demonstrates this difference by comparing the hydrophobic recovery of low-density polyethene (LDPE) and high-density polyethylene (HDPE). LDPE recovers to a lower energy state (higher water contact angle) than HDPE, although both materials retain a higher surface energy than the untreated materials, even after several weeks.

henniker plasma how long does plasma treatment last figure 1

Fig 1: Change in water contact angle(⁰) of High-Density Polyethylene (HDPE) and Low-Density Polyethylene (LDPE) after plasma treatment.

There are many other intrinsic properties of a polymer that may have an effect on the rate of recovery, such as crystallinity, polarity, conductivity etc.

Figure 2 demonstrates the differences between three different polymers after undergoing the same plasma treatment and being stored under the same conditions. It can be seen that, not only is the rate of recovery different, but some polymers are treated much more effectively than others, with polystyrene (PS) remaining in a high state of activation even after several weeks.

Once again, it can also be seen that all of the materials remain in an activated state and never fully recover to the untreated low energy state level.

henniker plasma how long does plasma treatment last figure 2

Fig 2: Water contact angle(⁰) of 3 different polymers after undergoing the same plasma treatment.

Duration of plasma treatment

There is some evidence that a longer exposure time to plasma may result in a higher number of surface and subsurface bonds of the material being broken by UV radiation from the plasma, leading to easier chain motion of molecules in the bulk of the material and hence a more rapid recovery process. Some research even states that plasma times of just 5 seconds are sufficient. Such short times however are not always enough for the first step removal of contamination and it’s therefore important to strike a balance.

Figure 3 shows the surface energy recovery behaviour of plasma treated PET for different plasma treatment times. Although the rate of recovery is faster for longer plasma treatment, this is still the most effective treatment time overall and results in a lower contact angle (higher surface energy) overall.

henniker plasma how long does plasma treatment last figure 3

Figure 3: Plasma treatment of PET polymer for 5 seconds and 100 seconds

Storage Conditions

Storage conditions of plasma-treated materials can have a large effect on the energy state of the surface. Higher temperatures can lead to faster hydrophobic recovery due to the increased ease of mobility of chain structures beneath the surface for example.

Figure 4 shows the effect of storage temperature on a water contact angle of plasma-treated PET. It can be seen that higher temperature storage conditions contribute to the rapid recovery of the sample. In this example, water contact angle results show that the surface energy returns to almost 90% of its previous value in less than one hour.

henniker plasma how long does plasma treatment last figure 4

Fig 4: Water contact angle(⁰) of PET polymer over time when stored at different temperatures.

Airborne contamination and the transfer of oil and salts from contact with bare hands also have a detrimental effect on surface energy.

Covering the plasma-treated material will prevent recontamination but care must be taken that the covering itself does not transfer or leech contamination. Figure 5 compares two samples following plasma treatment; one that has been covered and one that has been left uncovered. The uncovered parts display an enormous variation in contact angle over time, probably due to different types and degrees of contamination on different parts of the surface, whereas the covered samples show a more stable expected recovery over time.

                 henniker plasma how long does plasma treatment last figure 5

Fig 5: Water contact angle(⁰) of PET polymer over time when covered and handled with gloves, compared to uncovered and handled without gloves.

Type of plasma treatment

Another factor that can affect the rate of recovery of a plasma-treated material is the nature of the gas used in the plasma process. Different gases can introduce different functional groups onto the surface, which in turn leads to slightly different surface characteristics.

Figure 6 compares the measured water contact angle of plasma-treated PET for different process gases. The oxygen treated PET sample retained the lowest contact angle, although air showed the highest initial decrease. Air plasma processes are often perfectly suitable for treating materials due to the oxygen content within ambient air and also offer a cost-saving compared to using bottled gas.

 henniker plasma how long does plasma treatment last figure 6

Fig 6: Water contact angle(⁰) of PET polymer when plasma treated with differing process gasses.

Example Water Contact Angles

The following images show the change in water contact angle over time for a plasma-treated sample. Complete wetting of the sample can be seen immediately following plasma treatment, indicating high surface energy and excellent adhesion characteristics. The water contact angle increases over a 7-hr period as the sample slowly recovers, but always remains in a higher surface energy state than the untreated sample.

henniker plasma how long does plasma treatment last surface energy examples

Conclusions

Each material must be considered individually when questioning how long a specific plasma treatment will last, although overall, most polymers will retain a higher surface energy than the untreated polymer for several weeks.

In general, for the best results, it is better to perform printing/bonding processes as soon as is practically possible following plasma treatment, however, if that isn’t possible then it is worth considering the following:

  • Covering the parts if possible, using foil, not leaving the treated surface open to ambient air.
  • Always using powder-free gloves to handle plasma-treated parts.
  • Storing plasma-treated parts in as cool an area as possible, avoiding warm areas.
  • Reducing long treatment times. Oxygen plasma is capable of fully cleaning and activating a polymer surface within a few minutes.

Henniker have an extensively equipped plasma processing and testing laboratory in our UK headquarters where we can conduct trials to determine both the effectiveness and lifetime of plasma treatment on a wide range of samples.

Please contact us today if you would like to learn more.

Click here to download the lets talk about

REQUEST A QUOTATION OR FURTHER INFORMATION

See what our customers have to say

  • "The technical team at Henniker are very knowledgeable and supportive and always approachable. I have found it a pleasure to work with them."

    Simon Baxter - BAE Systems, MAI

    BAE
  • "Henniker guided us to choose the most suitable plasma unit for our application, ensured an accelerated delivery time & guided us through the very easy setup. We obtained quality results with their unit within minutes of setup & consistent results thereafter. The support they have provided has been rapid and helpful."

    Dr Ravi Desai - Making Lab, Francis Crick Institute

    Francis Crick Institute
  • "Henniker provided our team with excellent service during the course of our work together, the plasma cleaner arrived quickly and was installed with ease, giving us visible results from the outset and confirming that we made the right decision in choosing a local UK manufacturer."

    Dr Panagiotis Manesiotis BSc MRSC - Queen’s University Belfast

    Queens Uni Belfast
  • "Our customers and operations demand reliability at every level and were a key factor in our decision to choose a UK based manufacturer of plasma treatment equipment."

    Tom Doak - Trak Microwave

    Queens Uni Belfast
  • "Henniker’s after sales support is first class. They have always been extremely responsive if we have ever had need to call on them."

    Steve Rackham - Teledyne

    Teledyne
  • "Henniker’s plasma systems have delivered tangible benefits to us right from day one. The team there are very easy to work with."

    Ian Bruce - Coopervision

    Coopervision
  • "Henniker really stood out, both in their product range and technical knowledge. They are a great company to work with."

    Karthik Nair - University of Bradford

    University of Bradford
  • "We are very impressed with the ease of use and reliability of our plasma unit and were producing results within minutes of setting it up."

    Dr Neil Wilson - Warwick University

    Warwick University
  • "Our collaborative work with the team at Henniker was a very positive experience and one that we look forward to developing further."

    Ewen Kellar - TWI

    TWI
  • "Henniker provided a tailored product to match our exact requirements. They are a pleasure to work with."

    Dr Will Shu - Heriot Watt University

    Heriot Watt University

  • Huf
  • Kingspan
  • BOC
  • Maclaren
  • Cambridge Uni
  • Warwick Uni
  • Morgan Ceramics
  • QMUL
  • University Bradford
  • BAE
  • Imperial College London
  • Heriot Watt Uni
Henniker Plasma Logo

ISO logo

 

 

Connect with us

Henniker 3 Berkeley Court, Manor Park, Runcorn, WA7 1TQ, UK

+44 (0)1925 830 771   +44 (0)1925 800 035     info@plasmatreatment.co.uk